Review and verification of repair and strengthening design calculations for a heritage building undergoing comprehensive intervention. The scope encompassed foundation improvement strategies, enhancement of wall load-bearing capacity for both horizontal and vertical loads, floor system strengthening to provide diaphragm action and safe load transfer, façade restitution in accordance with original architectural character, and verification that all engineering and architectural components work together to ensure structural stability and long-term durability.